- Tool sharpening
- Grinding
- Milling
- Drilling
- Band sawing
- Plastic machining
- Routing & Chill Roll Cooling
AIR-MTC tool coolers uses a vortex tube to produce cold air at one end. Hot air is exhausted as waste at the muffled hot end. The cold air is also muffled and exits through the flexible hose, which is used to direct the air to the spot where cooling is required. A magnetic base allows for portability and easy mount of the unit to the machine.
Always use clean, dry compressed air. An Air Filter is supplied with every system to insure dry air. If oil is a major problem in the compressed air line, an oil removal filter is also recommended. The temperature of the air can be controlled by reducing the pressure using either a regulator or manual shut-off valve. A solenoid valve may also be connected into the machine operation to turn the air supply to the cooling unit on-off as it is needed, thereby conserving compressed air usage.
Model | Air Consumption | Capacity Watt (BTU/hr) | Sound level |
AIR-MTC15 | 15 SCFM | 322 (1100) | 73 dB(A) |
AIR-MTC25 | 25 SCFM | 527 (1700) | 73 dB(A) |
AIR-MTC30 | 30 SCFM | 615 (2100) | 73 dB(A) |
AIR-MTC40 | 40 SCFM | 849 (2900) | 73 dB(A) |
AIR-MTC tool cooling System are available with either a single point or dual point hose kit. The single point system is used for most drilling and grinding operations where point cooling is required. Milling, band sawing or other operations where the heat is generated over a larger surface area, require a dual point outlet to cover the larger area. To convert a single point system to a dual point system you can simply purchase the dual point hose kit.
“Click on the Model to View their individual catalogue”